Pair the wide shot with the nameplate
Take one wide photo that shows where each unit sits on the equipment pad, then take a close-up of its accessible nameplate. Check the close-up at full size before leaving. Use the same plain-language label in the photo filenames and inventory, such as filter pump or heater. Record the manufacturer, exact model, and serial number for each unit, and keep the invoice with the inventory.
Resolve substitutions against the installed unit
If the pump on the pad differs from the original order, use the installed nameplate to update the turnover record and reconcile the change with the supplier. If ENERGY STAR certification was specified, use the exact installed model to check for a matching listing. The directory includes categories for in-ground self-priming filter pumps and variable-speed pumps. Save the matching listing with the pump documents for the owner.
Hand over the confirmation or the open task
Check each manufacturer’s registration instructions and record who will submit the form and any applicable deadline. Obtain the owner’s authorization before submitting their details. If the form asks the owner to accept terms or make separate marketing choices, have the owner complete the registration. For builder-led submissions, verify the owner details and the installed model and serial numbers, then save the confirmation with the inventory. For owner-led submissions, show the owner the inventory row and nameplate photo they will need. At the walkthrough, have them find the information for one piece of equipment using their own copy.